PT1000 RTD TEMPERATURE PROBES

AX-PT series · IEC 60751 Class B · PTFE cable · −50 to +200 °C

AX-PT SERIES

The Axiom Thermal AX-PT series probe-type platinum RTD sensors combine a platinum element to IEC 60751 with an AISI 304 stainless-steel sheath and PTFE anti-corrosion lead wire. Waterproof, oil-proof and acid/alkali resistant, for temperature measurement in pipes, tanks, machinery and corrosive environments.

Key features

  • Platinum RTD element, measuring range −50 … +200 °C
  • Class B accuracy standard; classes 2B / A / 1/3B optional
  • Compact Ø4 × 30 mm probe, fast response, easy mounting
  • PTFE-sheathed lead wire: waterproof, oil-proof, acid and alkali resistant
  • 3-wire connection compensates lead resistance over long distances
  • Standard wire length 1.5 m, 0.5 … 5 m on request; OEM available

Applications

Pipes, tanks and reactors, machinery, HVAC, food machinery, chemical and corrosive environments, water and oil temperature measurement, environmental test chambers.

Technical specifications

Sensing elementPlatinum RTD to IEC 60751
Measuring range−50 … +200 °C
Accuracy classClass B standard (±0.3 °C at 0 °C); 2B / A / 1/3B optional
Wiring3-wire (red ×2 / blue ×1)
Max. excitation current≤ 5 mA
Insulation resistance≥ 100 MΩ (100 V DC)
Probe sizeØ4 × 30 mm (probe type, no fixing device)
Sheath materialAISI 304 stainless steel
Lead wirePTFE anti-corrosion sheath, 3-core tinned stranded copper, 1.5 m (0.5 … 5 m on request)
Protection classIP65 (probe and lead seal)
Response time≤ 10 s (in water, typical)
Ambient temperature−50 … +200 °C (probe)

Ordering codes

CodeDescription
AX-PT-2B-1.5MClass 2B, cable 1.5 m
AX-PT-B-1.5MClass B, cable 1.5 m
AX-PT-A-1.5MClass A, cable 1.5 m
AX-PT-B-0.5MClass B, cable 0.5 m
AX-PT-B-1MClass B, cable 1 m
AX-PT-B-2MClass B, cable 2 m
AX-PT-B-3MClass B, cable 3 m
AX-PT-B-5MClass B, cable 5 m

OEM and private label options

AccuracyClass 2B, A, 1/3B
Cable length0.5 … 5 m
ConstructionCustom accuracy, length and structure (OEM)

Installation and wiring

3-wire: two red wires on one end of the element, one blue wire on the other end. The 3-wire connection compensates lead resistance and is recommended for runs over 10 m. Notes: (1) wire colours may change without notice; (2) check that the RTD type matches the instrument setting before power-on; (3) do not exceed the rated temperature range.

Specifications subject to change without notice. Full resistance tables and dimensional drawings are included in the PDF datasheet.